6. Troubleshooting

6-26

April

2002

9128-A2-GB20-60

Physical Tests

Physical tests require the participation of your network service provider.

Main Menu

Test

[Network Physical Tests/Data Port Physical Tests/

DSX-1 Physical Tests/PRI Physical Tests]

If the unit does not have the ISDN PRI DBM feature, PRI Physical Tests does not
appear.

A FrameSaver unit’s physical tests screen for the network interface is shown
below.

Physical Tests Screen Example

The InjectErr function key at the bottom of the screen only appears when a Send
Pattern Test is Active. Select InjectErr to inject a single bit error into the pattern
being sent.

The ResetMon function key at the bottom of the screen only appears when a
Monitor 511 test pattern is Active. Select ResetMon to reset the monitor pattern
error counter.

CAUTION:

You should not run these tests with frame relay equipment attached;
you must disconnect the frame relay equipment and use external test
equipment.

main/test/network 9128-II

Device Name: Node A 5/26/2000 23:32

NETWORK 1 PHYSICAL TESTS

Test Command Status Results

Local Loopbacks

Line Loopback: Start Inactive 0:00:00

Payload Loopback: Start Inactive 0:00:00

Repeater Loopback: Start Inactive 0:00:00

Remote Loopbacks

Send Line Loopback: Down Send Inactive 0:00:00

Pattern Tests

Send: user-defined 0a0a Stop Active 0:00:00 - Errors 99999+

Monitor: user-defined0a0a Stop Active 0:00:00 - Errors 99999+

--------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

InjectErr

ResetMon