Send Remote Line Loopback

The remote Line Loopback (LLB) up and down codes are in-band codes that allow
control of a remote device. The LLB Up code invokes a line loopback in the remote
unit while the LLB Down code terminates the remote line loopback. Network
loopbacks are defined in AT&T TR 62411.

A remote LLB cannot be started when one of the following tests is active:

T

Any Loopback on the same interface.

T

Send Pattern Test on this network interface or any synchronous data port (Port
Use set to Synchronous) assigned to this interface.

T

Send V.54 or FT1 Loopback, or Data Channel Loopback on any synchronous
data port (Port Use set to Synchronous) and assigned to this network
interface.

T

Data Channel Loopback on the frame relay link on this network interface.

Procedure

To start and stop a Remote Line Loopback:

1. Follow this menu selection sequence:

Main Menu

Test

[Network Physical Tests/PRI Physical Tests]

2. Select the desired network interface (shown in the screen title).

3. Select the

Up

code in the Remote Line Loopback row to put a remote device

into loopback.

4. To start the test, highlight

Send

under Command in the Remote Line

Loopback row and press Enter. The code is sent for up to 10 seconds, or until
an acknowledgement is received from the remote end. The length of time that
the test has been running is shown in the Results column.

5. To stop the test, send the

Down

code to take the remote device out of

loopback.