Physical interface alarm defaults, B-19 – Paradyne 9128-II User Manual

Page 341

Advertising
background image

B. SNMP MIBs and Traps, and RMON Alarm Defaults

9128-A2-GB20-60

April 2002

B-19

Rising Event Operation

If a rising threshold is crossed during the interval shown in a table (e.g., frames
dropped by the network), the event is armed and an alarm is generated at the end
of the interval. Only one alarm per event per interval is generated. The alarm
condition persists until the event has been disarmed (reset).

The event is disarmed when a falling threshold has been crossed and the rising
threshold has not been crossed during an interval, allowing the event to return to
its original disarmed state.

Physical Interface Alarm Defaults

This alarm only applies to the FrameSaver unit’s network interface.

Table B-10. Network Physical Interface Alarm Defaults

Item

Sample
Type

1

MIB/Tag/OID

2

Interval

Event Type

Rising
Threshold
Default

Falling
Threshold
Default

Unavailable
Seconds

D

MIB:

DS1/E1 MIB (RFC 1406)

Tag:

dsx1TotalUASs

OID:

.1.3.6.1.2.1.10.18.9.1.5.I

900 secs
(15 mins)

Rising

1

1

1

D = Delta. Indicates that the calculated difference between the current value and the previous value is
contained in the MIB.

2

I in the OID = Interface ID of the frame relay link.