VEGA VEGASON 51V…53V User Manual

Page 15

Advertising
background image

VEGASON 51 V … 53 V

15

Types and versions

-

Configuration of measuring systems

15 sensors via one two-wire line on the processing system VEGALOG 571

Two-wire technology, power supply and digital output signals via one two-
wire line from the processing system VEGALOG 571.

15 sensors on one two-wire line.

Measured value indication integrated in the sensor.

Optionally external indicating instrument
(can be mounted up to 25 m separated from the sensor in Ex-area).

Adjustment with PC or adjustment module
(can be plugged into the sensor or external indicating instrument).

Max. resistance of the signal line 15

per wire or 1000 m cable length.

VEGALOG

571 CPU

VEGALOG

571 EV

2

2

CPU

2

2

2

4

2

4

2

4

Processings see also product information
"Signal conditioning instruments series 500"

Screened line in case of electromagnetic
interferences

1)

Processing system VEGALOG 571
with input cards in 19"-rack. 15
sensors on one module card and
two-wire line

Interface cable
RS 232

VEGASON 51 … 53
(15 sensors per two-wire line
can be individually grouped)

VEGA-
CONNECT 2

VEGADIS 50

Current outputs
Voltage outputs
Relays
Digital wiring
Fault signals
Connection to all Bus-
systems
Transistor outputs

1) Sensor lines should be looped in screened

cables. It is suitable to earth the cable
screens on both ends. However it must be
noted that no earth compensation currents
flow via the screens.
Earth compensation currents can be avoided
with earthing on both ends by connecting the
cable screen on one earth end (e.g. in the
switching cabinet) via a capacitor (e.g. 1

µ

F,

100 V) to the earth potential.