5 flow measurement, Rectangular flume, Khafagi-venturi flume – VEGA VEGASON 51V…53V User Manual

Page 31

Advertising
background image

VEGASON 51 V … 53 V

31

Mounting and installation

-

Flow measurement

The short examples on this page should give
just introductory information for your flow
measurement. Planning information is given
by the flume manufacturers and in special
literature.

Rectangular flume

- Installation of the sensor on the upstream

side

- Note distance to the overfall edge

(3 … 4 x h

max

)

- Installation centered to the flume
- Edge opening

2 x h

max

from ground

- Installation perpendicular to the liquid

surface

- Keep min. distance relating to h

max

- Min. distance of the edge opening of

downstream water

50 mm

Khafagi-Venturi flume

- Installation of the sensor on the inlet side
- Note distance to the Khafagi-Venturi flume

(3 … 4 x h

max

)

- Installation perpendicular to the liquid

surface

- Keep min. distance relating to the height of

damming h

max

4.5 Flow measurement

Flow measurement on open flumes

< min. distance

h

max

2 x h

max

Overfall edge

90

°

B

Flow measurement on open flumes

Upstream water

Downstream water

5 cm

90

°

3 … 4 x h

max

Khafagi-Venturi flume

90

°

h

max

Sensor

3 … 4 x h

max

Overfall edge

Advertising