VEGA VEGASON 51V…53V User Manual

Page 16

Advertising
background image

16

VEGASON 51 V … 53 V

Types and versions

-

Configuration of measuring systems

3 sensors per two-wire line via separator VEGATRENN 548 V Ex on the
processing system VEGALOG 571

Two-wire technology, power supply and digital output signals via one two-
wire line from the separator.

Three sensors on one two-wire line.

Measured value indication integrated in the sensor.

Optionally external indicating instrument
(can be mounted up to 25 m separated from the sensor in Ex-area).

Adjustment with PC or adjustment module
(can be plugged in the sensor or external indicating instrument).

Max. resistance of the signal line 7,5

per wire or 1000 m cable length,

note the permissible values for capacitance and inductance of the connec-
tion cable (see also approval certificates of the separators).

VEGALOG

571 CPU

VEGALOG

571 EV

CPU

VEGATRENN

548

VEGATRENN

548

VEGATRENN

548

2

2

2

2

2

2

2

2

2

2

2

2

VEGALOG

571 EV

VEGATRENN

548

VEGATRENN

548

2

2

2

2

2

2

Ex-area

Not Ex-area

Screened line in case of electromagnetic
interferences

2)

(see page 12)

Processing system
VEGALOG 571
(19" module card)

Input card of VEGALOG 571
(max. 15 sensors per card)

Separator VEGATRENN 548 V Ex
(max. 9 sensors per card)

Interface cable RS 232

VEGACONNECT 2

VEGADIS 50

Current and
voltage outputs
Digital wiring
Fault signals
Transistor outputs
Connection to all
Bus-systems
Relays

VEGASON 51 … 53
3 sensors per two-wire line, individual
grouping

Advertising