VEGA VEGASON 51V…53V User Manual

Page 19

Advertising
background image

VEGASON 51 V … 53 V

19

Technical data

Process connections

VEGASON 51

G 1

1

/

2

A,

1

1

/

2

" NPT

VEGASON 52

G 2 A,

2" NPT

VEGASON 53

DN 100 compression flange

Connection lines

Two-wire sensors
- supply and voltage via one two-wire line

line resistance max. 15

per wire or 1000 m cable length

Cross-section area of conductor

generally 2,5 mm

2

Earth connection

max. 4 mm

2

Cable entry

2 x M20 x 1,5 (cable diameter 5 … 9 mm)

CE-Conformity

VEGASON series 50 ultrasonic sensors meet the protective regulations of EMVG (89/336/
EWG) and NSR (73/23/EWG). The conformity has been judged acc. to the following stand-
ards:
EMVG Emission

EN 50 081 - 1: 1993

Susceptibility

EN 50 082 - 1: 1995

NSR

EN 61 010 - 1: 1993

Outputs and processinds

Display indication

Indication

optionally integral, scalable analogue and digital
measured value indication
optionally external measured value indication
powered by the sensor which can be mounted
up to 25 m from sensor

Signal output

Signal output

digital output signal in two-wire technology
(VBUS)

Two-wire technololy:
The digital output signal (meas. signal) is modulated to the power supply and processed in
the signal conditioning instrument or in the processing system.

Advertising