Mounting and installation

-

Installation error

4.7 Installation error

Foam generation

Strong foam on the product can cause faulty
measurements. Provide measures to avoid
foam, measure in a bypass pipe or use an-
other meas. principle, e.g. capacitive elec-
trodes of hydrostatic pressure transmitters.

Foam generation

Strong heat fluctuations

Strong heat fluctuations, e.g. due to the sun,
cause meas. errors. Provide a shield.

Strong heat fluctuations

Min. distance to the product

When the min. distance to the product is not
maintained, the instruments show wrong
measured values (see page 23). Mount the
instruments with the required min. distance.

Wrong directing to the product

If the sensor is not directed to the product
surface, weak measuring signals are caused.
Direct the sensor axis vertically to the prod-
uct surface to reach optimum meas. results.

Direct sensor vertically to the product surface