2 mounting instructions for flow measurement – VEGA VEGADIF 55 4 … 20 mA_HART User Manual

Page 12

Advertising
background image

Danger:
I

nstruments for oxygen applications should be unpacked just before

mounting. After removing the protective cover of the process fitting, the

label "O₂" will be visible on the process fitting. Penetration of oil,

grease and dirt should be avoided. Danger of explosion!

U

se the recommended cables (see chapter "Connecting to power

supply")

and tighten the cable gland.

Y

ou can give your VEGADIF 55 additional protection against moisture

penetration by leading the connection cable downward in front of the
cable entry. Rain and condensation water can thus drain off. This

applies mainly to outdoor mounting as well as installation in areas
where high humidity is expected (e.g. through cleaning processes) or
on cooled or heated vessels.

4

.2 Mounting instructions for flow measurement

+

1

2

4

3

Fig. 5: Measurement setup, flow measurement in gases with VEGADIF 55
1

VEGADIF 55

2

Three-fold valve block

3

Block valves

4

Orifice or impact pressure probe

à Mount VEGADIF 55 above the measurement loop so that

condensate can drain off in the process cable.

Oxygen applica-
tions

Moisture

Flow measurement in
gases

12

VEGADIF

55 • 4 … 20

mA/HART

4 M

ounting

31731

-EN

-081119