T

he point is highlighted in black, i.e. you can now edit this position.

1. P

ush "+" or "-" until "0" is displayed. 2. Confirm "0" with the "E" key.

C

ursor jumps to the next position. "↵" is displayed and is highlighted in

black, see next illustration.

W

ith "E" you save the new value and quit the editing mode, see next

illustration.

T

he new value for the damping is 30 s. You reach the next parameter

with "E". You return to the editing mode with "+" or "-".

E

xample: Adjust measurement end - assign 20 mA to the pressure

value 400 mbar.

T

he lower line on the local indication shows the existing pressure, here

400

mbar.

Take the pressure on the
instrument over as value

VEGADIF