7-4

Data subject to change without notice 7/07. © 2007 GE Drives

(9) Memory error Er1,

Keypad panel communication error Er2,
CPU error Er3

(10) Output wiring error

(11) Input Phase/Loss

Remedy faulty parts.

Er1, 2, 3 indicated. Abnormal

display or indication goes out.

Are there loose screws on

the terminal block?

Turn the power off then on

again after the CHARGE lamp

(CRG) goes off.

Is data displayed on the

LED monitor correctly?

Drive is normal.

Continue operation.

Are the connectors, plugs,

and ICs inserted correctly?

Is there noise generating

source nearby?

Drive may be faulty.

Contact GE Drives.

Output wiring error

Er7

Did the error occur

during tuning?

Are the braking unit and

braking resistor connected

incorrectly?

Faulty drive or error due

to noise, etc.

Contact GE Drives.

Connect

correctly or

replace the

cable.

Input phase loss

Lin

Are all main circuit power supply

terminals L1/R, L2/S and L3/T

connected to the power supply?

Is the U, V, W terminal wiring not

connected or is there an open

circuit?

The keypad panel

connector is loose.

Connect all three

phases.

Connect

correctly or

replace the

cable.

Secure the

connector.

Disable the

connection.

Is connection between

control terminals FWD,

REV - CM enabled?

Tighten the screws on

the terminal block.

Faulty drive or error

due to noise, etc.

Contact GE Drives.

Is there a significant

imbalance voltage

between phases?

Faulty drive or error

due to noise, etc.

Contact GE Drives.

Faulty drive or error

due to noise, etc.

Contact GE Drives.

YES

YES

NO

NO

NO

NO

YES

YES

YES

YES

YES

NO

NO

NO

YES

YES

YES

NO

NO

NO

Advertising