11 alarm information, 00 oc1 – GE Industrial Solutions AF-300 G11 User Manual

Page 48

Advertising
background image

4-11

Data subject to change without notice 7/07. © 2007 GE Drives

4.3.11 Alarm Information

Select 7. Alarm Information (ALM INF) on the Program Menu screen. A variety of operating data at the time the latest
alarm occurred is displayed. Use UP and DOWN to switch between the nine screens of alarm information data.

60.00

1.DATA SETTING
2.DATA CHECK
3. OPR MNTR
4. I/O CHECK

5. MAINTENANCE
6. LOAD FCTR

> 7. ALM INF

60.00

OC1

Fout=xxxx.xHz
Iout=x.xxA
Vout=xxxV
TRQ=xxx%

Code of latest alarm
(High speed blinking during alarm
mode only)
Output frequency at alarm
Output current at alarm occurence
Output voltage at alarm occurence
Torque calculation value at alarm
occurence

RUN

PRG > PRG MENU
F/D > LED SHIFT

FWD

OC1

TIME=xxxxxh
EDC=xxxV
TMPI=xxxx°C
TMPF=xxxx°C

Cumulative operating hours at alarm occurence

DC link circuit voltage at alarm occurence

Temperature inside drive at alarm occurence

Heat sink temperature at alarm occurence

Fref=xxxx.xHz
xxx xx xx xx

OC1

Setting frequency at alarm occurence
Operating status at alarm occurence
FWD/REV: Rotating
IL:

Current limiting

VL:

Voltage limiting

LU:

Under voltage

TL:

Torque limiting

OC1

REM

X2 X6

FWD

X3 X7

REV

X4 X8

X1

X5 X9

SIGNAL OFF, SIGNAL ON

Input terminal status at a alarm
occurence (terminals)

No. of communication errors at
alarm occurence: Keypad panel
No. of communication errors at
alarm occurence: RS 485
No. of communication errors at
alarm occurence: Options

OC1

NRK=xxxxx
NRR=xxxxx
NRO=xxxxx

Input terminal status at a alarm
occurence (communication)

SIGNAL OFF, SIGNAL ON

OC1

COM

X2 X6

FWD

X3 X7

REV

X4 X8

X1

X5 X9

Output terminal status at a alarm
occurence

SIGNAL OFF, SIGNAL ON

OC1

Y1

Y5

Y2
Y3
Y4

OC1

0/1 =xxx

xxx

-1

=xxx

xxx

-2

=xxx

xxx

-3

=xxx

xxx

Previous alarm

Before previous alarm

Two times before previous

No. of occurences
Alarm history
No. of occurences
Updated at alarm occurence. If the
cause of an alarm is the same as the
previous one, only the number og
occurences is incremented.

Multiple alarms
(Simultaneously
occuring alarms)

Alarm code

Up to four alarm codes can be dosplayed simultaneously.

OC1

5=xxx
4=xxx
3=xxx
2=xxx

Lastest alarm

PRG

FUNC