Data subject to change without notice 7/07. © 2007 GE Drives

Name

Digital I/O interface card

Type

OPCG11SDIO

Function

4 Digital Inputs

Binary code input of max. 16 bits or BCD input (sink/source changeable)

3 Digital Outputs

Binary code output of max. 8 bits

Input

Digital signal input (4 points) by short-circuiting terminals L1, L16 and M1
<Sink>
ON operation current:

4.5 mA max.

OFF operation voltage:

27 V max.

<Source>
ON operation current:

4.5 mA max.

OFF operation voltage:

27 V max.

Related function code:

o19, o20

Output

Digital signal output (3 points) by short-circuiting terminals between O1 to O6, and M2
<Sink>
ON operation current:

50 mA max.

OFF operation voltage:

27 V max.

<Source>
ON operation current:

-50 mA max.

OFF operation voltage:

27 V max.

Related function code:

o21

Power Source

Connection
Diagram

Remarks

Specifications

+24 Vdc (3.2 mA x 4 + 12.8 mA)

Used to set frequency and give an indication of operation using binary coded decimals for PLC and CNC control algorithms

L1/R

L2/S

L 3 / T

U

V

W

I16

I15

I14

I13

I12

I11

I10

I9

I8

I7

I6

I5

I4

I3

I2

I1(LSB)

M1

O8(MSB)

O7

O6

O5

O4

O3

O2

O1(LSB)

Ry

Ry

Ry

Ry

Ry

Ry

Ry

Ry

M2

CM

AF-300

G

1

1

S

OPC-G1

1S-DIO

Sink

G

M

@