13 data copy – GE Industrial Solutions AF-300 G11 User Manual

Page 50

Advertising
background image

4-13

Data subject to change without notice 7/07. © 2007 GE Drives

4.3.13 Data Copy

Select 9. Data Copy to display the Data Copy on the Program Menu screen. Read screen. A copy operation is then
performed in the following order: function data is read from the first inverter, the keypad panel is removed and attached to
a second inverter, the data from the first inverter is written to and stored in the second inverter.

The “verify” feature also makes it possible to compare and check differences in the data stored in the keypad panel and
the data stored in the inverter.

Read data

Write data

Attach keypad panel, Turn power ON.

60.00

RUN

PRG > PRG MENU
F/D > LED SHIFT

FWD

60.00

1.DATA SETTING
2.DATA CHECK
3. OPR MNTR
4. I/O CHECK

5. MAINTENANCE
6. LOAD FCTR
7. ALM INF
8. ALM CAUSE

> 9. DATA COPY

<DATA COPY>

READ

Data copy screen

Mode (read mode)

<DATA COPY>

READ

Reading

<DATA COPY>
30 HP-2

READ

COMPLETE

Data of drive type read
by keypad panel

Read complete

Remove keypad pananel

60.00

RUN

PRG > PRG MENU
F/D > LED SHIFT

FWD

60.00

1.DATA SETTING
2.DATA CHECK
3. OPR MNTR
4. I/O CHECK

5. MAINTENANCE
6. LOAD FCTR
7. ALM INF
8. ALM CAUSE

> 9. DATA COPY

READ

<DATA COPY>
30 HP-2

WRITE

<DATA COPY>
30 HP-2

WRITE

<DATA COPY>
30 HP-2

<DATA COPY>
30 HP-2

WRITE

COMPLETE

Write complete

Writing

Mode (write mode)

Drive type of data
stored by keypad panel

PRG

PRG

PRG

FUNC

DATA

FUNC

DATA

FUNC

DATA

FUNC

DATA

Advertising