GE Industrial Solutions AF-300 G11 User Manual

Page 146

Advertising
background image

13-3

Data subject to change without notice 7/07. © 2007 GE Drives

Name
Type
Function

To perform speed control by detecting motor rotating speed using a pulse generator

Specifications Control

3 to 3600 rpm (for 4-pole motor)
±0.02%
150% zero-speed (at ZERO signal ON) short time
100 (kp/s)

Applicable

Output Pulse:

20 to 3000 P/R (A, not A, B, not B)

Encoder

PG Power Supply:

+5 Vdc ± 10%/200 mA

(Generator)

Maximum Response Frequency:

100 kHz

Input Terminal

PI:

PG external power supply input

PO:

PG power supply output

CM:

Common

YA:

Input feedback PG phase A (+) pulse

*YA:

Input feedback PG phase A (-) pulse

YB:

Input feedback PG phase B (+) pulse

*YB:

Input feedback PG phase B (-) pulse

Power

Internal Power Supply:

+5 Vdc ± 10%/200 mA

1

Source

External Power Supply:

5 Vdc ± 10%

1

Use an external power supply when 200 mA is exceeded

Connection
Diagram

I. Drive Internal Power Supply

II. External Power Supply

Remarks

Speed Control Range:
Speed Control Accuracy:

PG feedback card (AF-300 G11 only)
OPCG11SPG2

Full quadrature speed control with the primary signal and its complement to reduce the effect of electrical noise where required

Starting Torque:
Maximum Number of Input Pulse:

L1/ R

L2 / S

L3 / T

U

V

W

M

YA

P O

* YA

YB

* YB

U

V

W

P G

J1

PG

M

5 Vdc

–10%

INT

EXT

G

G

P I

C M

P I

L1 / R
L2/ S

L3/ T

YA

* YA

YB

* YB

C M

J1

INT

EXT

P O

P I D
F e e d b a c k
C a r d

P I D
F e e d b a c k
C a r d

Advertising