Date, Time (local), and GMT (offset) fields

The

Date

field displays the current date in the Greenwich Mean Time zone.

The

Time (local)

field displays the current time in the local time zone.

The

GMT

field displays the amount of time, in hours and minutes, that the local time varies

from the GMT international time reference.

NOTE: Rather than using the following procedure, you can click the

Sync Time to PC

button to set the switcher to the internal time of your computer.

If desired, adjust any of these values as follows:

1.

Click in the desired field. The field changes to an editable field appropriate to the value
being change and the graphic cursor becomes a text cursor.

z

z

The

Date

field becomes a set date field, with the date in the

format (M)M/(D)D/YYYY. Leading zeroes are not shown.

z

z

The

Time (local)

field becomes a set time field, with the

time in the format HH:MM:SS (00:00:00 to 23:59:59).

z

z

The

GMT

field becomes a set offset field, with the offset in the format

±HH:MM (–12:00 to +14:00).

2.

Edit the field as desired to set the proper value. For time, remember to use 24-hour
time. Leading zeroes are optional.

3.

Press the <

Tab

> key on the keyboard or click in another field to exit the set date field.

4.

Click the

Take

button to make the date change take affect.

Sync Time to PC button

Clicking the

Sync Time to PC

button causes the computer you are operating to send its

internal time to the switcher in a set time command.

Use Daylight Savings check box

If desired, click in the

Use Daylight Savings

check box. When Daylight Saving Time is

turned on, the switcher automatically updates its internal clock between Standard Time and
Daylight Saving Time in the spring and fall on the date that the time change occurs in the
country or region selected. When Daylight Saving Time is turned off, the switcher does not
adjust its time reference.

NOTE: For Daylight Saving Time in Europe and Brazil, see the “

Set Daylight Saving

Time

” SIS command on page 84.

Administrator Password and User Password fields

The

Administrator Password

field displays the password required to log on to the

matrix switcher via the Ethernet port with all of the administrator rights and privileges. The

User Password

field displays the password required to log on to the matrix switcher via

the Ethernet port as a user, without all of the administrator rights and privileges. Passwords
are case sensitive and are limited to 12 upper-case and lower-case alphanumeric characters.
While you are logged on as a user, both password fields are masked with asterisks
(

************

) as a security measure.