NOTES: • The length of exposed wires is critical. The ideal length is 3/16 inch (5 mm).

z

z

If the stripped section of wire is longer than 3/16 inch, the exposed
wires may touch, causing a short circuit.

z

z

If the stripped section of wire is shorter than 3/16 inch, wires can be
easily pulled out even if tightly fastened by the captive screws.

Figure 7 identifies the tip, ring, and sleeve. A mono audio connector

consists of the tip and sleeve. A stereo audio connector consists of the
tip, ring and sleeve. The tip, ring, and sleeve wires are also shown on the
captive screw audio connector diagrams (see

figure 6

on the previous

page and

figure 9

on the next page).

Tip (+)

Sleeve ( )

Sleeve ( )

Ring (-)

Tip (+)

RCA Connector

3.5 mm Stereo Plug Connector

(balanced)

Figure 7.

Typical Audio Connectors

The audio level for each input can be individually set via the front panel or Ethernet or
RS-232 control to ensure that the level on the output does not vary from input to input
(see the “

Operation

” section, page 46; the “

Programming Guide

” section, page 76;

the “

Matrix Software

” section, page 105; and the “

HTML Operation

” section,

page 136).

d

Input Select switches — For inputs 1 through 8, set these DIP switches to

RJ-45

INPUT

SELECT

LOCAL

1 2 3 4

RJ-45

LOCAL

5 6 7 8

the Local (up) position to select the local (RGB video and audio) input. Set the
DIP switches to the RJ-45 (down) position to select the MTP input.

RS-232 Output Inserts

e

RS-232 Output Insert connectors — For bidirectional RS-232 data that is

routed to a specific (unswitchable) TP output, connect a serial device to one
of these 3.5 mm, 3-pole captive screw connectors. Figure 8 shows how to wire the
connectors.

Receive (Rx)

Transmit (Tx)

Ground ( )

Bidirectional

RS-232

Device

Ground ( )

Receive (Rx)

Transmit (Tx)

Rx

Tx

Do not tin the wires!

Figure 8.

RS-232 Output Insert Wiring

For the RS-232 Output Insert to be available on the TP output, the insert must be
enabled via an SIS command, the Windows-based control program, or an MTPX
Plus HTML page (see the “

Programming Guide

” section, page 734; the “

Matrix

Software

” section, page 106; and the “

HTML Operation

” section, page 134).

Each RS-232 output insertion is dedicated to the output with that number; for example,
RS-232 Output Insert 1 is always routed to the Output 1 TP connector (when enabled
as described in the note above), RS-232 Output Insert 2 is routed to the Output 2 TP
connector, and so on.

MTPX Plus 6400 Series Matrix Switchers • Installation