Optimizing the video, Mtp transmitter pre-peak selection, Mtpx level and peaking setting – Extron Electronics MTPX Plus 6400 Series User Guide User Manual

Page 118: Auto calibration, In the matrix softwar

Advertising
background image

Optimizing the Video

Each TP input has a level and peaking adjustment. Most MTP transmitters and each
MTPX Plus TP output has a pre-peaking feature. TP inputs and outputs have skew
adjustments. Set these adjustable features as follows for the best image quality:

NOTES: • For all of the settings in this section (with the exception of the Pre-Peak

switch on the transmitter in step 1), see the

MTPX Pictures settings

and

MTPX Configuration settings

menu items in “

Tools menu

,” on

page 105.

These settings can also be made using SIS commands or the built-in HTML

pages (see the “

Programming Guide

” and “

HTML Operation

” sections).

• Unless the TP cables are changed, these adjustments should need to be made

only once, during installation.

Before you start optimizing, set all input level and peaking, input and output skew, and
output pre-peak settings to either zero or off.

MTP Transmitter Pre-Peak Selection

For inputs from MTP T 15HD products only If the cable between the MTP transmitter
and the MTPX Plus is 200 feet (61.0 m) or longer, turn the Pre-Peak switch on the
transmitter to on. For shorter cables, turn the switch off.

MTPX Level and Peaking Setting

Auto calibration

The simplest and surest way to set the input level and peaking is to use the included MTP
signal generator and the auto-calibration utility within the Matrix Switchers Control Program
as follows:

NOTE: To manually set the input level and peaking, see “

Manual calibration

.”

1.

Disconnect the power and RJ-45 cables at the MTP transmitter connected to the input
to be adjusted.

2.

Connect the two cables to the included MTP signal generator.

3.

If the input cable between the transmitter and the MTPX Plus is longer than 200 feet
(61.0 m), place the Pre-Peak switch on the MTP signal generator to on (see figure 54).

Pre-Peak on (up) (shown)

Pre-Peak off (down)

Power LED

Figure 54.

MTP Signal Generator

NOTE: The MTP Signal Generator does not work on cable lengths over 400 feet

(120 m). Set the level and peaking to its maximum value of 255.

4.

In the Matrix Switchers Control Program, click

Tools

>

MTPX Picture

settings to open

the MTPX Picture Settings window (see

figure 46

on page 106).

MTPX Plus 6400 Series Matrix Switchers • Matrix Software 112

Advertising