Reset button and led, Power, Fans – Extron Electronics MTPX Plus 6400 Series User Guide User Manual

Page 25: Reset button and led power fans

Advertising
background image

Reset Button and LED

k

Reset button and LED — The recessed Reset button initiates four levels of matrix

RESET

switcher reset. For four different reset levels, press and hold the button while the
switcher is running or while you power up the switcher.
See “

Rear Panel Operations

” in the Operation section for details.

z

z

Events (mode 3) reset — Toggles event monitoring on and off.

z

z

IP settings (mode 4) reset — Reset the IP functions of the switcher.

NOTE: The IP settings reset does not replace any user-installed firmware.

z

z

Absolute (mode 5) reset — Restore the switcher to the default factory conditions.

z

z

Hard reset — Restore the switcher to the default factory conditions and return the
switcher to the default firware that shipped with the unit.

NOTES: • Factory loaded firmware is active until it is replaced or the power is

cycled.

Hard reset does not clear the current configuration.

Power

l

Primary and Redundant AC power connectors — Plug standard IEC power cords

into these connectors to connect the switcher to 100 VAC to 240 VAC, 50 or 60 Hz
power sources.

WARNING: The power connector is wired double pole with neutral fusing.

NOTE: For the most reliable power, connect the a power cord from the Redundant

power connector to either an uninterruptible power source or to a power
source that is completely independent from the primary power source.

m

Primary and Redundant power supply indicator LEDs —

Green — Indicates that the associated power supply is operating within normal
tolerances.
Red — Indicates that the associated power supply is operating outside the normal
tolerances or has failed. See “

Removing and Installing a Power Supply Module

” in

the “Maintenance and Modifications” section to replace the power supply.

Fans

n

Primary and Redundant cooling fans — Cool the equipment. If a fan has failed,

replace it at your earliest opportunity. See “

Removing and Installing a Fan Module

in the “Maintenance and Modifications” section to replace the fans.

MTPX Plus 6400 Series Matrix Switchers • Installation

19

Advertising