Command/Response Table for SIS Commands (continued)

Command

ASCII Command

(Host to Unit)

Response

(Unit to Host)

Additional Description

Save, recall, and directly write presets (continued)

Write room outputs

EX2$

,

X@

1

,

X@

2

, ...

X@

n

MR

]

See notes.

Mpr

X2$

,

X@

1

,

X@

2

, ...

X@

n

]

NOTES: • A room can contain a maximum of 16 outputs (

X@

s).

• An output can belong to only one room.

• The maximum number of rooms (

X2$

s) is 10.

Example:

E

8,3,Ø4,5,6MR

}

Mpr8,Ш3,Ш4,Ш5,Ш6

]

Outputs 3, 4, 5, and 6 are assigned to room 8.

Read room outputs

EX2$

MR

}

X2$

,

X@

1

,

X@

2

, ...

X@

n

]

NOTE: If no outputs have been assigned to the room, the switcher returns [unassigned]

]

.

Example:

E

3MR

}

Room•#Ш3••••,Ш1,Ш2,Ш8,Ш9

]

Outputs 1, 2, 8, and 9 are assigned to room 3.

Save current ties as a room
preset

X2$

*

X2@

,

Rmm

X2$

•Spr

X2@]

Command character is a comma.

NOTE: You must have assigned outputs to a room (

EX2$

,MR

}

) before you can save a room preset.

Example:

3*9,

RmmØ3•SprØ9

]

Save current ties as preset 9 for room 3.

Recall room preset

X2$

*

X2@

.

Rmm

X2$

•Rpr

X2@]

Command character is a period.

Read room outputs

EX2$

MR

}

X2#

,

X@

1

,

X@

2

, ...

X@

n

]

NOTE: The default name (

X2#

) is the room number with four trailing spaces: “Room•#

X2$

••••.”

Example:

E

3MR

}

Room•#Ш3••••,Ш1,Ш2,Ш8,Ш9

]

Outputs 1, 2, 8, and 9 are assigned to room 3.

Clear room preset ties

E

+

X2$

*

X2@

PØ*!

]

Rmm

X2$

•Spr

X2@]

Clear all ties in room

X2$

preset

X2@

.

Directly write a room preset

E

+

X2$

*

X2@

P

X!

*

X@

!

X!

*

X@

%

X!

*

X@

$ ...

X!

*

X@

!

}

Enter as many ties as are valid for this
configuration. The ! tie command, & tie, and
% tie commands are all valid and equivalent.

Rmm

X2$

•Spr

X2@]

Example:

+7*3P12*7&11*5&4*5%6*6!

Esc

Brackets are shown to separate ties for clarity
only. Create preset 3 for room 7, which ties
input 12 to output 7, input 11 to output 5,
input 4 to output 5, and input 6 to output 6.

RmmØ7•SprØ3

]

Lock (executive) modes

NOTE: See “

Setting the Front Panel Locks (Executive Modes)

” in the Operation section for more information on the Lock modes.

Lock all front panel
functions

1X

Exe1

]

Enable Lock mode 1.

Lock advanced front panel
functions

2X

Exe2

]

Enable Lock mode 2.

Unlock all front panel
functions

ØX

ExeØ

]

Enable Lock mode 0.

View lock status

X

X1#]

NOTE:

X!

= Input number

00 – maximum number of inputs for your matrix size (00 = untied)

X@

= Output number

01 – (maximum number of outputs for your matrix size)

X1#

= Lock status

0 = Lock mode 0

1 = Lock mode 1

2 = Lock mode 2

X2@

= Global or room preset number

01 – 64 (global) or 01 – 10 (room)

X2#

= Name

12 characters maximum

Upper- and lower-case alphanumeric characters and _ / and spaces are valid.

X2$

= Room number (for room presets)

01 – 10

MTPX Plus 6400 Series Matrix Switchers • Programming Guide

78