E zxxx, Query firmware version (verbose) – Extron Electronics MTPX Plus 6400 Series User Guide User Manual

Page 87

Advertising
background image

Command/Response Table for SIS Commands (continued)

Command

ASCII Command

(Host to Unit)

Response

(Unit to Host)

Additional Description

Resets (continued)

Reset whole switcher

E

ZXXX

}

Zpx

]

Clear all ties and presets, reset all all audio
gains to 0 dB, and reset volume to 100%.

Absolute reset

E

ZQQQ

}

Zpq

]

Similar to Reset whole switcher, plus
clear all UART ports, reset the IP address to
192.168.254.254, and reset the subnet mask
to 255.255.000.000.

Information requests

Information request

I

V

X2*

X

X2(

•A

X2*

X

X2(]

V

X2*

X

X2(

shows the video matrix size.

A

X2*

X

X2(

shows the audio matrix size.

Request part number

N

X3)]

See “

Part Numbers

.”

NOTE: There are up to three separate sets of firmware on which the switcher can report: the controller firmware, which is the overall

control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest optional controller
firmware update, which is available at

www.extron.com

.

Query firmware version

Q

X3!]

Example:

Q

1.23

]

The factory-installed controller firmware
version is 1.23 (sample value only).

Query controller firmware
version (verbose)

ØQ

X3!

-

X3@

-

X3@]

Provide a detailed status of the Ethernet protocol
firmware, the controller firmware, and any
firmware upgrade. An asterisk (*) marks the
firmware that is running. A caret (^) marks
that the firmware has a bad checksum or an
invalid load. ?.?? marks that firmware is not
loaded.

Response description:

Ethernet protocol firmware version-controller firmware version-updated firmware version

]

Example:

Øq

Ethernet

protocol

firmware

Description

MTPX firmware version

Updated firmware version

* indicates the version running

Upload date and time

1.00-1.23(1.81-MTPX 64 Series -Wed, 05 Jan 2011 00:00:00 GMT)-1.13*(1.81-MTPX 64 Series -Wed, 12 Jan 2011 16:39:21 GMT)

Request system status

S

X3#

X3#

X3#

X3#

X3#

X3#

X3$

X3%

X3%

X3#

X3#

X3#

X3$

X3%

X3%

X3%

X3%

X3%

X3^

X3^

X3^

X3^]

Response description:

+5V•–5V•+12V•–12V•+2.5V•–2.5V•Temp 1•Fan 1 RPM•Fan 2 RPM•+9V•–9V•+3.3V•Temp 2•Fan 3 RPM•Fan 4 RPM•Fan 5 RPM•

Fan 6 RPM•Fan 7 RPM•Pri 1 PS status•Red 1 PS status•Pri 2 PS status•Red 2 PS status

]

Example:

S

- 2.5 V power system at 2.49 V

Internal temperature at sensor 2 is 77.0° F

Fan 4 rotating at 2,766 RPM

12.00 V power system at 12.02 V

5.06•-5.03•12.02•-11.90•2.50•-2.49•+77.00•02766•02812•8.94•-8.90•3.31•+77.00•02766•02766•02721•02812•02766•1•1•1•1

NOTE:

X2*

= Number of inputs

48 or 64

X2(

= Number of outputs

32, 48, or 64

X3)

= Part number

See “

Part Numbers

X3!

= Firmware version number to second decimal place (n.nn)

X3@

= Verbose firmware version-description-upload date and time (see above).

X3#

= Voltage

Voltage, polarity (positive or negative) and magnitude

X3$

= Internal temperature

Degrees Fahrenheit

X3%

= Fan speed

RPM

X3^

= Power supply status

1 = Ok

0 = Out of tolerance or failed

MTPX Plus 6400 Series Matrix Switchers • Programming Guide

81

Advertising