Functions / options / designs, Structure of the control head, Functions / options / designs 5.4 – Burkert Type 8681 User Manual

Page 14

Advertising
background image

14

System Description

short mechanical and pneumatic installation times.

For increased safety requirements (e.g. in the explosion-risk area) a seal or a hood safeguard using plastic self-

cutting screws (3 mm diameter, approx. 10 mm length; e.g. Ejot PT screws K 30 x 10) are required.

conform to the ATEX Directive 94/9/EC (Dust ATEX category 3D and Gas ATEX category 3G - see chapter

6.2. )

functions / Options / designs

5.4.

structure of the Control Head

5.4.1.

Electronics module with
connection terminals,
service interface and
Teach-In buttons
(back side)

Solenoid valve 3

Solenoid valve 2

Solenoid valve 1

Cable gland
(back side)

Exhaust air connection (3/R)

Mechanical manual
control (red lever)

Supply pressure
connection(1/P)

Working connections

(2/A1 - 3)

Flow restriction screw(s)
for P and R
(2 per solenoid valve)

Solenoid valve 3 (2/A3)

Solenoid valve 2 (2/A2)

Solenoid valve 1 (2/A1)

Position measuring system
with LED's in three colors

Silencer in the exhaust air

connection (3/R), not shown

Sealing lug
(on lower housing part)

2 locking screws (shoulder
screws M5); no sealing
function, merely as protection
against pulling off from the
hub flange

Locking groove (3x)

Fig. 1:

Structure of Control Head Type 8681

english