120 V AC - Design

Danger!

risk of electric shock if the pe connection is not connected!

the PE connection must be connected!

Clamp the protective conductor to the PE connection.

Check correct grounding.

Close the housing observing the notes contained in chapter "

8. Opening and Closing the Housing".

note!

ensure ip protection!

To ensure IP protection, the union nuts of the cable glands must be tightened in accordance with the cable

sizes or dummy plugs used (approx. 1.5 Nm).

If an external initiator is not used, the cable gland (wrench size 19, Ø 3 - 6 mm) must be tightly sealed with

the dummy plug (Ø 5 - 6 mm) supplied from the factory!

note!

use of the control head in explosive atmosphere

Only use cables and cable glands that are allowed for the respective application area, and mount the cable

gland according to the respective operating instructions!

Close all unnecessary openings with lock screws/plugs approved for explosions area!

120 V aC electronics Module, terminal Strip Configuration:

Solenoid valve

connection with

status

LED for Valve 1

Terminal strip

Protective

conductor

(protection earth)

Power supply

(L/N)

Service inter-

face

DIP switches for

color coding the

LEDs

Connection

for the exter-

nal initiator

Feedback

signals

S1-S4 OUT

Control sole-

noid valves

Y1-3

Teach-In buttons

T1-3

Solenoid valve con-

nection with status

LEDs for Valves 2

& 3

120 V AC electronics module

Fig. 25:

english

Control Head Type 8681