Number of solenoid valves, Pneumatic interfaces, Manual control – Burkert Type 8681 User Manual

Page 16

Advertising
background image

16

System Description

number of solenoid valves

5.4.3.

The control head for process valves has been designed for single-acting and double-acting valve actuators as
well as for double-seated and multi-position valves.

type of use

number of solenoid valves
(3/2-Way solenoid Valve WWc*)

Repeater

0

Control head for single-acting actuators

1

Control head for double-acting actuators **

2

Control head for double-seated valves with integrated aeration of both
valve seats

3

*

WWC = circuit function C = 3/2-way valve; closed in rest position, output A unloaded

** both drive chambers currentless deaerated

pneumatic interfaces

5.4.4.

Intake & exhaust air connections:

G 1/4

Working connections:

G 1/8

Integrated non-return valves in the solenoid valves' exhaust air duct

Actuation of Connection 2/A1 (Solenoid Valve 1; normally the main stroke of the process valve) using the mag-

netic manual control that is externally accessible.

Special silencers with a high flow-rate capacity to connection 3/R have already been mounted.

The interior of the housing is protected against excessive overpressure, for example due to leakages, by a

pressure-relief valve with output into the joint exhaust air connection 3/R.

Manual Control

5.4.5.

Standardly, the control head provides the following:

a magnetic manual control that is easily accessible from the outside on the basis of encoded magnetic fields

for Solenoid Valve 1 (Connection 2/A1), as well as

a mechanical manual control accessible when the hood is open on each equipped solenoid valve.

the magnetic manual control has the following advantages:

the control head does not need to be opened

a simple activation tool for opening & closing Solenoid Valve 1 (main stroke) -

helpful for maintenance on the process valve

LED-display for the Activated Manual Control status, meaning service mode

(see chapter

16. LED - Color Assignments and 17. Service Mode / Manual Control )

For a detailed description of the manual control, see chapter

17. Service Mode / Manual Control .