Changing the valves, Changing the valves 19.3 – Burkert Type 8681 User Manual

Page 83

Advertising
background image

83

Replacement of Components and Modules

installation procedure:

Carefully insert the entire electronics module into the recess in the lower housing part.

Plug the electronics module carefully onto the contact pins for the position measuring system.

Refasten the electronics module with the Torx T10 screw (torque 0.4 Nm).

Reattach the electrical connections.

Check DIP switch positions (4-switch block for color coding, 8-switch block on DeviceNet electronics module

for address and Baud rate) and set the previously noted switch settings, if necessary.

If necessary, set AS interface address and jumper positions.

Perform Teach-In process (see chapter

15.1. Setting the Position Measuring System (Teach-In)).

Be sure to work carefully and cautiously, so that the electronics are not damaged.

Close the housing observing the notes contained in chapter "

8. Opening and Closing the Housing".

Changing the Valves

19.3.

According to the design, zero to three valve modules have been installed in the control head. The valves have
been designed with the flow restriction equipment for intake and exhaust air and must be installed as a valve
module.

Valve module from above

Flow restriction

screws

Torx screws (T10),

tightening torque:

1 Nm

note:

Disassemble/assemble the valves in upright position as there is
otherwise a risk that the non-return valve falls out!

Valve module

Fig. 32:

procedure:

Open the housing observing the notes contained in chapter "

8. Opening and Closing the Housing".

If necessary, mark the electrical connections to ensure correct assignment during reinstallation.

english

Control Head Type 8681