Description, Area of application, General description – Burkert Type 8045 User Manual

Page 13: Description of the name plate, Flow

Advertising
background image

9

Description

5.

DeScrIpTIon

5.1.

Area of application

The 8045 flowmeter is intended exclusively to measure flow rates in liquids.

The device makes it possible to switch a solenoid valve or activate an alarm thanks to a transistor output and,
for some versions, by means of two relay outputs, fully configurable and to establish a control loop thanks to a
4-20 mA current output.

The versions also equipped with a digital input make it possible to remotely activate a function.

5.2.

General description

The device comprises both a flow sensor operating on Faraday's law and a transmitter with display.

The device is equipped with a 4-20 mA current output (analogue output, called AO1), a digital output (configured
as a pulse output by default, called DO1) and two totalisers.

Some versions are equipped with two relay outputs (called DO2 and DO3) and one digital input (called DI1).

The device operates on a 3 wire system and needs a 18-36 V DC power supply.

The electrical connection is made on the terminals blocks of the electronic board within the transmitter, through
two M20 x 1,5 cable glands.

5.3.

Description of the name plate

M

ade in Franc

e

1

2

5

6

7

8

9

11

12

3

4

10

FLOW 8045 SST LONG

SUPPLY: 18-36V 300 mA

DO1: 5-36V= 100mA

DO2/3:250V 3A Max

DI1: 18-36V= 10mA

IP65

Fluid: PN16:-15/110°C

S/N 11 162

00449673

W43M

13

FLOW

14

1. Measured value and type of the device
2. Specification of the flow sensor
3. Specification of the DO1 digital output
4. Specification of the DO2 and DO3 relay outputs
5. Electrical power supply and current

consumption

6. Manufacturing code
7. Conformity logo
8. Warning: Before using the device, take into

account the technical specifications described

in these operating instructions.

9. Fluid temperature range and fluid nominal

pressure

10. Protection class of the device
11. Specification of the DI1 digital input
12. Serial number
13. Order code
14. Shows the flow direction

Fig. 1:

name plate of the 8045 flowmeter

English

Type 8045