Operatingandfunctions

8.3.

Description of the navigation keys and the status
leDs

• Selecting the displayed

parameter

• Confirming the settings

Status LED of relay DO3 (LED ON
= contact closed)

• Reading the messages

• Scrolling through the parameters

• Selecting the figure on the left

• Scrolling up the

parameters

• increment the figure

selected

Device status LED: see
following table.

Status LED of relay DO2 (LED ON
= contact closed)

Device status
leD

Status of the device

Green

The device operates correctly.

Orange

A warning message is generated.

Press the

key for 2 seconds in the Process level to access the message. See chap.

“9.5.5” for the meaning of the message.

Furthermore, a relay output (DO2 or DO3) or the transistor output DO1 switches if it is
configured in the "WARNING" mode (see Fig. 39

or Fig. 42)

Red

A fault message is generated and a 22 mA current is sent on the current output.

Press the

key for 2 seconds in the Process level to access the message. See chap.

“9.5.4” for the meaning of the message.

Blinking,
whatever the
colour

• the DI1 digital input is active,

• or a check for the correct behaviour of the outputs is running (see chap. “8.7.3”)

• or a flow zero point calibration procedure is running (see chap. “8.7.2”),

• or the daily totalizer is kept at zero.