Fig. 34 – Burkert Type 8045 User Manual

Page 43

Advertising
background image

39

Operatingandfunctions

8.6.7.

configuring the transistor output Do1 as a pulse output

When the DO1 transistor output is configured as a pulse output, a pulse is transmitted on the output each time
the parametered volume of fluid has been measured by the device.

OUtPUt

DO1

PULsE

0......9

Is only displayed if the unit chosen in
the "UNIT" parameter is in litres or m

3

.

Choose the volume unit of a pulse.

DO2

LitRE

m3

PU=01.000

Enter the volume of fluid (value between 0,000 and 9999,9)
for which a pulse is transmitted on the transistor output. If
the unit chosen in the "UNIT" parameter is in gallons, enter a
pulse in gallons.

To deactivate the pulse output, set PU to zero: the output is
always open and no pulse is transmitted.

Confirm

Fig. 34:

Configuration of the transistor output DO1 as a pulse output