General data – Burkert Type 8045 User Manual

Page 18

Advertising
background image

14

Technicaldata

10

9
8
7
6
5
4
3
2
1
0

0

+20

+40

+60

+80

PVDF (PN10) /

PP (PN10)

P (bar)

PVC + PP

A

PVC (PN10)

T (°C)

Metal

8045 with flow sensor in PVDF

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

-20

0

+20 +40 +60 +80 +100 +120

PVDF (PN10)

PVC (PN10)

PP (PN10)

T (°C)

P (bar)

PVC + PP

PVDF

A

DN100 for measuring

devices with a clamp con-

nection (PN10)

Metal

(PN16)

1)

1)

Except DN100 for measuring devices with a clamp connection

8045 with flow sensor in stainless steel

A: range of use

Fig. 6:

Fluid pressure /temperature dependency for a 8045 with PVDF flow sensor or stainless steel flow sensor and
a fitting S020 in metal, PVC, PVDF or PP

6.3.2.

General data

Pipe diameter

DN6 to DN400

Type of fitting

S020

Min. fluid conductivity

20 µS/cm

fluid temperature

• 8045 with flow sensor in PVDF

• 8045 with flow sensor in stainless steel

The fluid temperature may be restricted by the fluid
pressure, the material the flow sensor is made of and
the material the S020 fitting used is made of. See “Fig.
6”.

• 0 to +80 °C

• -15 to +110 °C

Fluid pressure

• 8045 with flow sensor in PVDF

• 8045 with flow sensor in stainless steel

The fluid pressure may be restricted by the fluid
temperature, the material the flow sensor is made of,
the material the S020 fitting used is made of and the
DN of the S020 fitting. See “Fig. 6”.

• PN10

• PN16

English

Type 8045

Advertising