Technicaldata

Flow rate measurement

• Measurement range

• Accuracy, after a teach-in calibration has been made

• Accuracy, with the K factor of the fitting used

• Linearity

• Repeatability

• 0,2 to 10 m/s

• ±0,5 % of the measured value

1)

• ±3,5 % of the measured value

1)

• ±0,5 % of the full scale

1)

• ±0,25 % of the measured value

1)

Determined in the following reference conditions: fluid = water, water and ambiant temperatures = 20 °C, upstream and

downstream distances respected, appropriate pipe dimensions.

6.3.3.

electrical data

Power supply

• 18-36 V DC, filtered and regulated

• oscillation rate: ±5 %

Current consumption

300 mA max. (at 18 V DC)

transistor output Do1

• type

• function

• frequency

• Electrical data

• duty cycle if f > 2 Hz

• min. pulse duration if f < 2 Hz

• protections

• NPN / PNP (wiring dependent), open collector

• pulse output (by default), user configurable

• 0-250 Hz

• 5-36 V DC, 100 mA max.

• 1/2

• 250 ms

• galvanically isolated, and protected against over-

voltages, polarity reversals and short-circuits

relay outputs (Do2 and Do3)

• operating

• electrical data of the load

• max. breaking capacity

• life span

• hysteresis (by default), configurable, normally open

• 250 V AC / 3 A or 30 V DC / 3 A (resistive load)

• 750 VA (resistive load)

• min. 100000 cycles

current output Ao1

• specification

• max. loop impedance

• 4-20 mA, sink or source (wiring dependent), 22 mA

to indicate a fault

• 1300 W at 36 V DC, 1000 W at 30 V DC, 700 W at

24 V DC, 450 W at 18 V DC