Burkert Type 8045 User Manual

Page 70

Advertising
background image

66

Maintenanceandtroubleshooting

9.5.5.

resolution of problems without message generation and
device status leD orange

Device
status
leD

current
output
Ao1

output Do1
and/or Do2
and/or Do3

message
displayed

possible cause

recommended action

orange

4-20 mA Switched

1)

"PULS.
OVF"

The value parametered
for the pulse output is
wrong (generated fre-
quency is > 250 Hz).

Increase the value of the
PU parameter (see chap.
“8.6.7”).

orange

4-20 mA Switched

1)

"NEG.
FLOW"

The measured flow rate
is negative (although the
display shows a positive
flow rate).

Check that the reverse fluid
circulation has no conse-
quences on the process.

Else, mount the device on
the pipe such as the arrow
on the housing indicates the
flow direction.

orange

4-20 mA Switched

1)

"WARN.
LOW"

The measured flow rate
is below the authorized
low limit.

This message appears
when the flow rate
is monitored (see
chap. 8.7.5).

Check the flow rate in the
pipe and its consequences
on the process.

If necessary, clean the flow
sensor then calibrate the flow
zero point.

orange

4-20 mA Switched

1)

"WARN.
HIG"

The measured flow rate
is above the authorized
high limit.

This message appears
when the flow rate
is monitored (see
chap. 8.7.5).

Check the flow rate in the
pipe and its consequences
on the process.

If necessary, clean the flow
sensor then calibrate the flow
zero point.

orange

4-20 mA Switched

1)

"DISP. OVF" The real flow rate cannot

be displayed (display is
saturated).

Except the display,
the device operates
depending on the earl
flow rate.

Adjust the unit or the number
of decimals in the UNIT
parameter of the Parameters
menu so that the display can
show higher values.

orange

4-20 mA Switched

1)

"LIN. LOST" The factory calibration is

lost.

The device measures
wrong values.

Take contact with the retailer.

orange

4-20 mA Switched

1)

"CAL. FAIL"

The flow zero point cali-
bration failed.

Follow the calibration con-
ditions described in chap.
8.7.2.

1)

If the output is configured to switch when a warning message is generated. See chap. 8.6.5.

English

Type 8045

Advertising