Operatingandfunctions

8.4.

using the navigation keys

you want to...

press...

move between parameters within a level or a menu.

to go the next parameter.

0......9

to go to the previous parameter.

access the Parameters menu

ENTER

+

simultaneously for 5 s, in the Process level

access the Test menu.

0......9

+

+

ENTER

simultaneously for 5 s, in the Process

level

access the Information menu.

for 2 s, in the Process level, when the device status

LED is orange or red.

reset the daily totalizer.

0......9

+

simultaneously for 2 s, when the daily totalizer

is displayed in the Process level

select the displayed parameter.

ENTER

confirm the displayed value.

ENTER

modify a numerical value.

0......9

to increase the blinking digit.

to select the digit at the left of the blinking digit.

0......9

+

to move the decimal point.

8.5.

Details of the process level

This level is active by default when the device is energized.

12.6 L/s

16.45 mA

87654 L

231 L.

0......9

> 2 s

Resetting the daily totalizer.

Value of the measured flow rate, displayed in the unit chosen in the "UNIT" parameter
of the Parameters menu.

Value of the current output, proportional to the measured flow rate.

Value of the main totalizer, volume of fluid counted by the device since the last reset.

Value of the daily totalizer (identified by a dot after the volume units), volume of fluid
counted by the device since the last reset.

0......9

+

0 L/s.

The displayed flow rate is set to 0 (a dot is displayed after the
flow rate units if the "CUT-OFF" function is active) because
the measured flow rate is below the threshold value defined in
the "CUT-OFF" parameter of the Parameters menu. See chap.
“8.6.16”.