Encoder connections without the eitb, Encoder connections without the eitb 59, Table 2.18—hd-15 encoder signal connections 59 – Watlow PPC-2000 User Manual

Page 83

Advertising
background image

PPC-2000 User’s Guide

Chapter 2: Hardware Installation

Doc.# 30002-00 Rev 2.3

Watlow Anafaze

59

Figure 2.44 EITB Differential Quadrature

Connections: Input 1 and 2 Shown

Encoder Connections without the EITB

Encoders may be connected directly to the PPC-2030 module.
Table 2.17 and Table 2.19 on page 60 indicate the functional
pinout for HD-15 connectors connected to the Encoder In
Analog Out module connectors J1 and J2.

Table 2.18

HD-15 Encoder Signal Connections

1

The AnaWin3 name is shown for the Encoder In Analog Out module with address

11 on the first PPC-2000 in the system. Refer to Inputs on page 127 for a full
explanation of analog input naming. Both count and frequency are measured for
each input.

Module

I/O

Number

Connector and Pin

Number

AnaWin3 Name

(Input Spreadsheet)

1

Phase 1

Phase 2

+

-

+

-

Count 1
Frequency 1

J3-1

J3-2

J3-3

J3-10

PPC1:EIAO 11.1.1 C
PPC1:EIAO 11.2.1 F

Count 2
Frequency 2

J3-6

J3-7

J3-8

J3-11

PPC1:EIAO 11.1.2 C
PPC1:EIAO 11.2.2 F

Count 3
Frequency 3

J4-1

J4-2

J4-3

J4-10

PPC1:EIAO 11.1.3 C
PPC1:EIAO 11.2.3 F

Count 4
Frequency 4

J4-6

J4-7

J4-8

J4-11

PPC1:EIAO 11.1.4 C
PPC1:EIAO 11.2.4 F

Q1

1+

1-

Q2

2-

2+

1+

1-

2-

2+

8 (input 2 phase 1+)

9 (input 2 phase 1-)

10 (input 2 phase 2+)

11 (input 2 phase 2-)

2 (input 1 phase 1+)

3 (input 1 phase 1-)

4 (input 1 phase 2+)

5 (input 1 phase 2-)

12 (COM)

12 (COM)

EITB

Advertising