2-3-3 Updating Configuration

This section lists the configuration options that exist in the ENSCRIBE files which can be modified
via the Storage Analyzer

Runtime Admin

&

Alert Admin

interface.

Table 5 Configuration Options and Descriptions

Item UI

Reference

Possible Values

Description

Run time

Runtime
Admin

Hour (00-23) and
Minute (00-59)
(Default is 23:59)

This defines in hour and minute of the day when the
collection will start running.

Run days

Runtime
Admin

One checkbox for
each of the days in
the week (Default all
7 days are checked).

The days on which the SA Host is supposed to r
gather data. It is possible to uncheck all the days.

CPU utilization for
Collector process

Runtime
Admin

One or more CPU’s
on which the SA Host
process will be run,
with a valid Process
priority value(2-180)
(Default is CPU 00
with a priority value of
142)

This is the number of parallel SA Host processes to
run for the daily data collection. Each of the
processes is assigned a disk and as soon as that
process is done collecting data for the disk, it is
assigned a new disk; until all the disks have been
processed The SA Host processes run with the
specified process priority.

Volume to store
daily collection
data.

Runtime
Admin

Selected volume from
a list of Volumes on
the Node (Default is
the Storage Analyzer
installation Volume)

The volume where daily collection data files are
stored. Inside the specified volume, data files are
collected in sub volume that follows the
SAyymmdd” format.

Data retention
period.

Runtime
Admin

Positive Integer
between 0-180
(Default is 180)

This is the maximum number of days to retain data
collected. Once the retention period is over the data
files and associated will be deleted.

File old age
criteria.

Runtime
Admin

Positive Integer
between 0-32767
(Default is 365)

This is used to report old files by collecting data
about files that have not been opened for the
specified number of days (or more).

File Index levels.

Runtime
Admin

Positive Integer
between 0-255
(Default is 3)

This is used to report reloadable files by collecting
data about files whose index level matches at least
the specified value.

Disk

Alert Admin

Selected disk from a
list of available disk
names.

This is used to specify the disk for which the alerts
are to be generated. For disk alerts, $* can be
specified which means that all the disks will be
scanned for matching the criteria.

Sub volume

Alert Admin

* Selected sub volume

from a list of available
sub volume names.

This is used to specify the sub volume for which the
alerts are to be generated.

Enable / Disable
Alert

Alert Admin

YES / NO – by
checking the
appropriate option
(Default is Enabled)

This is an indicator of whether the alert should be
checked or not.

EMS Event #

Alert Admin

Positive Integer (0-
9999). No default
value.

This is the user defined EMS Event # for the
generated alert message.

Alert severity

Alert Admin

Critical or Normal
(Default is Normal)

Used to assign type to the generated alert EMS
message (i.e. normal or critical).

Advertising