Displaying layer 3 system parameter limits – Brocade Communications Systems Layer 3 Routing Configuration ICX 6650 User Manual

Page 153

Advertising
background image

Brocade ICX 6650 Layer 3 Routing Configuration Guide

135

53-1002603-01

Modifying and displaying Layer 3 system parameter limits

The Layer 3 system parameter limits for IPv6 models are automatically adjusted by the system and
cannot be manually modified.

Displaying Layer 3 system parameter limits

To display the Layer 3 system parameter defaults, maximum values, and current values, enter the
show default value command at any level of the CLI.

The following example shows the output on a Brocade ICX 6650 device.

Brocade#show default value

sys log buffers:50 mac age time:300 sec telnet sessions:5

ip arp age:10 min bootp relay max hops:4 ip ttl:64 hops

ip addr per intf:24

when multicast enabled :

igmp group memb.:260 sec igmp query:125 sec hardware drop: enabled

when ospf enabled :

ospf dead:40 sec ospf hello:10 sec ospf retrans:5 sec

ospf transit delay:1 sec

when bgp enabled :

bgp local pref.:100 bgp keep alive:60 sec bgp hold:180 sec

bgp metric:10 bgp local as:1 bgp cluster id:0

bgp ext. distance:20 bgp int. distance:200 bgp local distance:200

System Parameters Default Maximum Current

ip-arp 4000 64000 64000

ip-static-arp 512 6000 6000

multicast-route 64 8192 8192

Advertising