Brocade Communications Systems Layer 3 Routing Configuration ICX 6650 User Manual

Page 473

Advertising
background image

Brocade ICX 6650 Layer 3 Routing Configuration Guide

455

53-1002603-01

Displaying VRRP and VRRP-E information

Table 84

shows a description of the output for the show ip vrrp stat and show ip vrrp- extended stat

commands.

TABLE 84

CLI display of VRRP or VRRP-E statistics

Field

Description

Interface statistics

Interface

The interface on which VRRP or VRRP-E is configured. If VRRP or VRRP-E is
configured on more than one interface, the display lists the statistics
separately for each interface.

rxed vrrp header error count

The number of VRRP or VRRP-E packets received by the interface that had a
header error.

rxed vrrp auth error count

The number of VRRP or VRRP-E packets received by the interface that had an
authentication error.

rxed vrrp auth passwd mismatch
error count

The number of VRRP or VRRP-E packets received by the interface that had a
password value that does not match the password used by the interface for
authentication.

rxed vrrp vrid not found error
count

The number of VRRP or VRRP-E packets received by the interface that
contained a VRID that is not configured on this interface.

VRID statistics

rxed arp packet drop count

The number of ARP packets addressed to the VRID that were dropped.

rxed ip packet drop count

The number of IP packets addressed to the VRID that were dropped.

rxed vrrp port mismatch count

The number of packets received that did not match the configuration for the
receiving interface.

rxed vrrp ip address mismatch
count

The number of packets received that did not match the configured IP
addresses.

rxed vrrp hello interval mismatch
count

The number of packets received that did not match the configured Hello
interval.

rxed vrrp priority zero from
master count

Indicates that the current Master has resigned.

rxed vrrp higher priority count

The number of VRRP or VRRP-E packets received by the interface that had a
higher backup priority for the VRID than this Layer 3 switch backup priority for
the VRID.

transitioned to master state
count

The number of times this Layer 3 switch has changed from the backup state to
the master state for the VRID.

transitioned to backup state
count

The number of times this Layer 3 switch has changed from the master state to
the backup state for the VRID.

Advertising