M-code definition, 2 f o lders – ACU-RITE MILLPWRG2 User Manual

Page 121

Advertising
background image

ACU-RITE MILLPWR

G2

103

6.2 F

o

lders

M-Code Definition

The following is a list of available M-Codes. Be advised that many
M-codes are machine dependant, and often machine manufacturers
will add, and/or remove some M-Codes.

† Represents supported M-codes.

M-Code List

M-Code

Description

Comment

M*

All other M codes not listed will generate a run-time error.

M0

Program Stop

This command pauses the program. Press GO to resume.

M1

Optional Program Stop

This command pauses the program if the Optional Stop run option is
selected. Press GO to resume.

M2

Program End

This command stops the program after completing of the block. The
cursor moves to the beginning of the program. The current settings are
reset to default values.

M3

Spindle On (CW)

If spindle control hardware is present, the spindle is turned on or off
automatically. If the hardware is not present, the operator is prompted
to turn the spindle on or off and/or to set the speed.

M4

Spindle On (CCW)

M5

Spindle Off

M6

Tool Change

M6 is not necessary. A tool change occurs when the Tool Selection
command is processed.

M7

Coolant On (Mist)

If the AMI hardware is present, the coolant is turned on or off
automatically. If the hardware is not present, the operator is prompted
to turn the coolant on (mist), on (flood), or off.

M8

Coolant On (Flood)

M9

Coolant Off

M30

Program End w/ Pallet Shuttle

MILLPWR

G2

does not support control of a pallet changer. This code has

the same effect as M2.