Job clock - parts counter, Probing, Job clock - parts counter probing – ACU-RITE MILLPWRG2 User Manual

Page 197: 1 set u p

Advertising
background image

ACU-RITE MILLPWR

G2

179

9.1 Set

u

p

Job Clock - Parts Counter

The parts counter appears on the status bar when in DRO mode, or
running a program. This is useful to track how many times the current
program has run and therefore how many parts have been completed.

Here, setting the parts counter, stopping or starting the Job Clock are
setup. The Job Clock will provide an estimate of time to machine the
part, provide a stop watch, parts counter, and overall Job time.

Preset a starting count by entering the value in the Parts field.

Press the Set Count soft key to set the counter to the field value.

Press the Reset Count soft key to set the Parts field to 0.

The Job Clock is also displayed on the status bar, and operates like a
stop watch. It is started, or stopped by the user from the JOB SETUP
dialogue.

The Pause Clock soft key will pause the Job Clock temporarily.

The Resume Clock soft key will resume the Job Clock after it has
been paused.

The Reset Clock soft key will stop, and reset the Job Clock to 0.00.

There is no MILLPWR

G2

requirement for these features. They are

provided to the operator for job assistance, and informational
purposes.

Probing

When using a probe, the radius of the tip of the probe is used for
establishing the location of an edge of a work piece. The value of the
probes radius will be used in all applicable dialogues when the probe
is the selected tool.

Select the PROBING Radius field.

Enter the tip radius of the probe.

Press the USE key to enter the data.

The parts counter resets to 0 when a new program is
loaded.

Advertising