9.1 Set

u

p

To set the X axis Travel Limits:

Select the TRAVEL LIMITS X Axis field.

Move the table by pressing the Move Table soft key, then use the
right and left ARROW keys, or manually move the table with the hand
wheel.

Move the table to the left to locate the right side table travel limit
stop.

With the table in the required location, press the Set Right softkey.

Move the table to the right to locate the left table travel limit stop is
to be set, and press the Set Left softkey.

Press the Exit soft key to exit Move Table, and accept the X Axes
limit stop locations, and return to the dialogue.

The next field can not be accessed unless the Exit soft key, or
CANCEL

key is pressed. Each axes must be set individually in order to

return to the dialogue form.

To set the Y axis Travel Limits:

ARROW

down to the TRAVEL LIMITS Y Axis field.

Move the table by pressing the Move Table soft key, then use the UP
ARROW

key to move the table towards the column. The DOWN ARROW

key is used to move the table away from the column. The table can
also be manually moved with the hand wheel.

Move the table towards the column to where the Inside table travel
limit stop is to be set.

With the table in the required location, press the Set Inside softkey.

Move the table out to where the Outside table travel limit stop is to
be located.

With the table in the required location, press the Set Outside
softkey.

Press the Exit soft key to exit Move Table, and accept the Y Axes
limit stop locations, and return to the dialogue.

The X axis travel field will now update to show the
maximum allowable travel distance between the left and
right table travel limit stops.

The Y axis travel field will now update to show the
maximum allowable travel distance between the Inside
and Outside table travel limit stops.