Tool table, Error log, 1 set u p – ACU-RITE MILLPWRG2 User Manual

Page 201

Advertising
background image

ACU-RITE MILLPWR

G2

183

9.1 Set

u

p

Tool Table

MILLPWR

G2

contains a tool table that can store the diameter, length,

unit of measure, and tool type for up to 99 tools. MILLPWR

G2

only

requires that you provide the tool's diameter; however, it may be
helpful to the operator if additional information is provided so that each
tool is easier to identify from the tool list. Chapter 4 provides complete
information regarding the tool table. See "Tool Table" on page 44

Set up the tool table so that the tools used most often appear first.

From SETUP, press the Tool Table soft key.

Error Log

MILLPWR

G2

includes a built-in error log that will record system error

messages. If an error is detected, MILLPWR

G2

will automatically

record the date, along with a brief description of the error.

If an error is present that prevents running of another program the
front panel indicator light will flash.

Press the Info soft key to display additional information on the
highlighted error which will open in its own display window. The
additional information includes Cause and suggested correction
Action.

Press the Detail soft key to display the detailed information
available on the source of the error. This will also open in its own
display window.

Press the Delete soft key to clear the highlighted message.
Pressing the Delete All soft key will clear all messages. Pressing
the Delete All soft key will also exit the Error Log dialogue.
Pressing the Delete soft key will only exit the dialogue if there was
only one error message.

To exit the Error Log, press the Exit soft key.

A quick method for deleting all errors in the log is to press
the “0” on the numeric keypad.

Advertising