7 Demonstration Program

7.

1 Demonstr

ation Pr

ogr

am

Programming the lower angle Line

Next, the line that angles in to the part from the lower vertical line will
be added.

Press the LINE key.

MILLPWR

G2

has again assumed that it will continue from where it left

off, and all fields are filled in except for the TO: fields. The cursor is also
located here, in the first field.

Using the numerical keypad, enter the following information:

In the TO: X2 field enter .75.

Now press the ABS/INCR key.

The INC field next to the X2 field has opened. Press the X1 soft key.
X1 is displayed in this field next to the X2 field.

ARROW

Down once to the Y2 field.

In the TO: Y2 field enter 0.00.

Press the USE key.

Next, the upper angle line will be added to the program.

If the X1 soft key had not been pressed, then INCR would
not have been used, and MILLPWR

G2

would assume that

ABS is to be continued.