Rockwell Automation 20G PowerFlex 750-Series AC Drives User Manual

Page 329

Advertising
background image

Rockwell Automation Publication 750-RM002B-EN-P - September 2013

329

Integrated Motion on the EtherNet/IP Network Applications for PowerFlex 755 AC Drives

Chapter 6

Table 19 - Permanent Magnet Motor Data Instance to Parameter Cross Reference

Permanent Magnet Motor Model Motion Axis Parameters

Table 20 - Permanent Magnet Motor Model Instance to Parameter Cross Reference

Integrated Motion on EtherNet/IP Instance

Drive Parameter

Motor Overload Limit

P413 [Mtr OL Factor]

Motor Rated Continuous Current

P26 [Motor NP Amps]

Motor Rated Output Power

P30 [Motor NP Power]

Motor Rated Peak Current

P422 [Current Limit 1]

Motor Rated Voltage

P25 [Motor NP Volts]

Motor Type

P35 [Motor Cntl Mode]

Rotary Motor Poles

P31 [Motor Poles]

Rotary Motor Rated Speed

P28 [Motor NP RPM]

Integrated Motion on EtherNet/IP Instance

Drive Parameter

PM Motor Rotary Voltage Constant

P86 [PM CEMF Voltage]

PM Motor Resistance

P87 [PM IR Voltage]

PM Motor Inductance

P88 [PM IXq Voltage]
P89 [PM IXd Voltage]

Advertising