Rockwell Automation Publication 750-RM002B-EN-P - September 2013

371

Integrated Motion on the EtherNet/IP Network Applications for PowerFlex 755 AC Drives

Chapter 6

• Position Loop:

You can manually adjust the Loop Bandwidth, Integrator

Bandwidth, Integrator Hold and Error Tolerance values.

• Velocity Loop:

You can manually adjust the Loop Bandwidth, Integrator

Bandwidth, Integrator Hold, and Error tolerance (when used as a Velocity
Loop) values.

Motion Generator Section:

The Motion Generator is a subset of the Motion

Direct commands that lets you control the axis motion for tuning.

Additional Tune Section:

This section enables adjustment of multiple settings

of the axis properties:

• Feedforward Tab:

Lets you adjust the Velocity Feedforward percentage

and Acceleration Feedforward percentage.

• Compensation Tab:

Lets you adjust the System Inertia percentage and

Torque Offset percentage.

• Filters Tab:

Lets you adjust the Torque Low Pass Filter Bandwidth and

Torque Notch Filter Frequency.

• Limits Tab:

Lets you adjust the Peak Torque Limit Positive / Negative

percentages and Velocity Limit Positive / Negative Units per Second
values.

• Planner Tab:

Lets you adjust the Maximum Speed, Maximum

Acceleration, Maximum Deceleration, Maximum Acceleration Jerk, and
Maximum Deceleration Jerk values.