Rockwell Automation 20G PowerFlex 750-Series AC Drives User Manual

Page 425

Advertising
background image

Rockwell Automation Publication 750-RM002B-EN-P - September 2013

425

Appendix A

562

Set

Commutation Self-Sensing Current

-

-

N

N

N

PM Motor only
O-Value = #

563

Set

Commutation Polarity

-

-

N

N

N

PM Motor only

250

Set

Feedback Commutation Aligned

-

-

Y

Y

Y

O-Enum
2 = Motor Offset (N)
3 = Self-Sense (Y)

570

Set

Frequency Control Method

-

R

-

-

-

O-Enum
128 = Fan/Pump Volts/Hertz (Y)
129 = Sensorless Vector (Y)
130 = Sensorless Vector Economy (Y)

600

Get

Output Frequency

-

R

Y

Y

Y

610

Set

Stopping Action

-

R

R

R

R

O-Enum
2 = Ramped Decel Disable (FPV/Y)
3 = Current Decel Hold (PV/N)
4 = Ramped Decel Hold (PV/Y)
128 = DC Injection Brake (IM/Y)
129 = AC Injection Brake (IM/Y)

612

Set

Stopping Time Limit

-

-

N

N

N

613/354

Set

Resistive Brake Contact Delay

-

N

N

N

N

PM Motor only

614

Set

Mechanical Brake Control

-

N

N

N

N

615

Set

Mechanical Brake Release Delay

-

N

N

N

N

616

Set

Mechanical Brake Engage Delay

-

N

N

N

N

870

Set

DC Injection Brake Current

-

Y

Y

Y

Y

Ind Motor only

872

Set

DC Injection Brake Time

-

Y

Y

Y

Y

Ind Motor only

871

Set

Flux Braking Enable

-

Y

Y

Y

Y

Ind Motor only

627

Set

Power Loss Action

-

Y

Y

Y

Y

O-Enum
2 = Decel Regen (Y)

628

Set

Power Loss Threshold

-

Y

Y

Y

Y

629

Set

Shutdown Action

-

N

N

N

N

O-Enum
1 = Drop DC Bus (N)

630

Set

Power Loss Time

-

Y

Y

Y

Y

637

Get

Converter Capacity

-

N

N

N

N

638/262

Get

Bus Regulator Capacity

-

N

N

N

N

646

Set

Motor Overload Action

-

N

N

N

N

O-Enum
1 = Current Foldback (N)

647

Set

Inverter Overload Action

-

Y

Y

Y

Y

O-Enum
1 = Current Foldback (Y)
128 = Reduce PWM Rate (Y)
129 = PWM Foldback (Y)

659

Get

CIP Axis Alarms

Y

Y

Y

Y

Y

904

Get

CIP Axis Alarms - RA

Y

Y

Y

Y

Y

695

Set

Motor Overspeed User Limit

-

Y

Y

Y

Y

697

Set

Motor Thermal Overload User Limit

-

Y

Y

Y

Y

699

Set

Inverter Thermal Overload User Limit

-

N

N

N

N

Table 30 - PowerFlex 755 Safety Drive Module Optional Attributes

ID

Access

Attribute

N

F

P

V

T

Conditional Implementation

Advertising
This manual is related to the following products: