Load backlash axis properties configuration – Rockwell Automation 20G PowerFlex 750-Series AC Drives User Manual

Page 334

Advertising
background image

334

Rockwell Automation Publication 750-RM002B-EN-P - September 2013

Chapter 6

Integrated Motion on the EtherNet/IP Network Applications for PowerFlex 755 AC Drives

Table 23 - Load Instance to Parameter Cross Reference

Load Backlash Axis Properties Configuration

Load Backlash Axis Properties

Reversal Offset resides in the controller’s Motion Planner

Integrated Motion on EtherNet/IP Instance

Drive Parameter

Total Inertia

P76 [Total Inertia]

Torque Offset + Torque Trim

P686 [Torque Step]
Torque Offset is summed together with the Torque

Trim value, which is sent synchronously to the drive
every Coarse Update Period. The Torque Trim value is
available for real time “active” torque corrections and
the Torque Offset value is available for constant system
torque compensation.