14 Install the Module

4. Remove the module to the right of the base you are removing, noting

that the interlocking portion of the base sits under the adjacent module.

5. Use a small-bladed screwdriver to rotate the orange DIN rail locking

screw on the mounting base to a vertical position. releasing the locking
mechanism.

6. Lift the mounting base straight up to remove.

Wire the Modules

To wire the thermocouple input modules, refer to the figures.

1734-IT2I Module Overview

WARNING

If you connect or disconnect wiring while the field-side power
is on, an electrical arc can occur. This could cause an explosion
in hazardous location installations. Be sure that power is
removed or the area is nonhazardous before proceeding.

Thermocouple

Input

Module

Status

Network

Status

1734

IT2

NODE:

0

1

43923

Module status

Network status

Status of input 0

Status of input 1

0+

Shield

0-

1+

1-