Forge Package Updater

The Package Updater utility is a program which updates the drive and operates
on both Windows and Windows CE platforms. It is supplied by Rockwell
Automation.

It can be provided as a separate .PKG file, or can be embedded within this utility.

Figure 73 - Package Updater

Update the HMI Interface Board

1.

Open the Package Updater utility (

Figure 73

).

Refer to the Windows Explorer section under

Drive Menu on page 24

.

2.

Enter the IP address of the drive in the fields, or press Select to choose
from a list of discovered drives.

Once selected, the Drive’s name (if configured) is displayed to confirm the
entered IP address. If using an external file, press Browse and select the
appropriate file.

Once the desired IP address of the drive is either selected or entered, the drive
must be placed in Download Mode.

3.

Click Internal, and click Update.

Advertising