GV3000/SE Operator Interface Module (OIM) User Guide, Version 2.0

Step 3. Press

to clear the screen and continue. The screen shown in figure

5.5 is displayed.

Step 4. Press

to start self-tuning. A message and the motor speed during

self-tuning are displayed, as shown in figure 5.6. In the few minutes that
self-tuning takes, you can view other outputs by going to monitor mode.

Note that if you go into monitor mode during self-tuning, you must return to program
mode at the completion of self-tuning to see the following screens. Self-tuning is
complete when the drive stops running.

Figure 5.4 – Attention Screen Displayed After Enabling Self-Tuning

Figure 5.5 – Self-Tuning Enabled Screen

Figure 5.6 – Self-Tuning Active Screen