Using Quick Start to Program the Drive

5-7

Step 5. When self-tuning is complete, the OIM displays one of these messages:

Self Tuning has updated the gains: Self-tuning was successfully
completed.

Emergency stop or fault stop occurred during self-tuning. Self-tuning
aborted: The self-tuning was not completed because of a fault or because

was pressed. See TORQUE SELF-TUNE RSLT, U.009 (in the Self

Tuning Parameters menu), and the software I/M for descriptions of the
possible results. Repeat self-tuning when the problem is corrected.

Step 6. Press

to clear the message and return to the Main Menu (if self-tuning

was performed as part of the Quick Start procedure) or the Self Tuning
Parameters menu.

5.4.3 Exiting Before Self-Tuning is Complete

If you have not activated self-tuning by pressing

, you can stop self-tuning by

pressing

. You are returned to the Main Menu if self-tuning was enabled from

Quick Start, or to the Self Tune Parameters menu.

If self-tuning has been activated, press

to stop self-tuning. This causes a

self-tuning drive fault. See the next section for more information on self-tuning drive
faults.

5.4.4 What To Do If a Fault Occurs During Self-Tuning

If a fault occurs during self-tuning:

the motor coasts to stop, regardless of the setting of STOP TYPE (P.025).

the drive logs a self-tuning fault, which must be reset and cleared. See chapter 7 for
more information on clearing and resetting faults.

Once the drive is stopped, the results of the self-tuning are stored in TORQUE
SELF-TUNE RSLT (U.009). See the software I/M for more information.

When the problem that caused the fault is corrected, repeat the self-tuning procedure.