6-2

GV3000/SE Operator Interface Module (OIM) User Guide, Version 2.0

Output power: Output power of the drive in kilowatts. This is intended for display
purposes as a general indication of output power in kilowatts.

Reference: The speed or torque the drive attempts to reach when the drive is
running. The reference will be Manual or Auto if the drive is regulating speed, or
Torque Reference if the drive is regulating torque.

6.1.2 Selecting the Outputs to Monitor

You can view one of three monitor mode screens. The first monitor mode screen
shows all six of the monitored outputs. The second monitor mode screen shows four
of the monitored outputs in a larger text size. The third monitor mode screen shows
two of the outputs without labels, in larger text so the values can be read from a
distance. You can change the outputs you want to monitor at any time.

To select monitor mode:

Step 1. Press

until the key indicator switches from PROGRAM to MONITOR.

The monitor mode screen with six outputs is displayed, as shown in figure
6.1.

Step 2. To display the four-output monitor mode screen, press

again.

The screen shown in figure 6.2 is displayed.

Step 3. To display the two-output monitor mode screen, press

again.

A sample of this screen is shown in figure 6.3. You cannot change
the value of the manual reference while this screen is displayed.

Figure 6.2 – Monitor Mode Screen with Four Outputs Displayed

Figure 6.3 – Monitor Mode Screen with Two Outputs Displayed